Repair the Firebox for the Fire It Will Actually Hold

Ask About Fireplace Repair

What This Job Involves

A firebox that has burned wood for decades shows it: split brick, eroded joints, a hearth slab that has dropped. Some owners repair it to keep burning logs. Others repair it because a gas set will sit right on that floor. Either way we replace damaged firebrick or refractory panels, repoint with heat-rated mortar, reset the hearth and refit the doors, with the price on paper first.

Firebrick or refractory panels replaced
Joints redone with heat-rated mortar
Sunken or split hearth reset
Doors rehung or replaced
Floor readied for a gas set if one is planned

Repairs That Depend on What You Burn Next

Firebox damage in Fullerton homes tends to follow the same pattern. The back wall of a masonry firebox takes the most heat, so its mortar joints open first and the firebrick behind the grate cracks. In factory built units, the refractory panels split along their length and the steel behind them can rust where water has come down the flue. Under a wood fire, all of that has to be fixed, because a gap in the firebrick lets heat reach the brick and framing behind it. The picture changes if you are converting. A gas log set burns cooler than oak, but it still sits in the firebox, so cracked firebrick and open joints still get repaired. An insert is different. It slides into the opening as its own sealed box, and minor cracks in the old firebox behind it no longer carry heat. We tell you which camp each item falls in before you decide.

The damper is the other common repair. A plate rusted solid, a handle that turns without moving anything, or a frame that has cracked and no longer seals will all leak heat in winter and smoke on windy nights. If you stay with wood, we repair the damper or replace it with a new one in the throat or a sealing type at the top of the flue. If you are going to a vented gas set, the damper has to be locked partly open for safety, so a full replacement may not be worth paying for. If you are fitting an insert, the old damper usually comes out to make room for the liner. Every repair is listed on a written quote with a line for each item. Each answer changes the price, so the fuel gets settled first.

Doors, Screens and the Face Around the Opening

Glass doors and screens wear out in ways that look minor and are not. A door that will not latch lets sparks out on a wood fire. A frame that has pulled away from the brick leaves a gap that leaks room air up the flue all night. We realign, reseal or replace doors, and fit new screens sized to the opening. On a gas conversion, most door sets stay, but some log sets need the doors open while running, and the maker's instructions decide that rather than our preference. The surround and the hearth in front of the opening get looked at too: loose tile, a cracked hearth slab, or a mantel that has been scorched all go on the list. Scorch marks on a wood mantel are a warning that it sits too close to the fire, not just a cosmetic problem.

If the list grows long, a repair stops being the sensible answer and a remodel becomes worth pricing. That is usually the case when the firebox, the face and the hearth all need work, or when the owner wants a different look anyway. The remodel page explains how a new surround is planned around a gas unit. For straightforward repairs, the visit starts with an inspection of the firebox, the price comes in a written quote, and nothing begins until you have approved it. Use the contact page to describe what is broken and which fuel you are using now. For owners partway through a decision, it can make sense to repair only the safety items now and leave the cosmetic ones until the fuel is settled. A firebox that will soon hold an insert does not need new brick on its back wall, and the quote flags items like that.

How Murdoch Chimney Group Works

Flue Before Fuel

The chimney is checked before any gas unit is chosen

Options Compared

Logs, insert and sealed unit laid out next to each other

Figures on Paper

Scope and cost written down before tools come out

Photos With Reports

What we saw, shown as well as described

More from our service list

Chimney Sweep

Tar and soot cleared out of a wood flue, often the first job before gas logs or an insert move into the same opening.

Read more

Chimney Inspection

Flue, crown, damper and firebox reviewed so you learn what a gas switch would ask of the chimney you already own.

Read more

Chimney Repair

Broken tile, open joints and leaks put right in the order a gas appliance needs them, before anything is lit.

Read more

Fireplace Inspection

Firebox, hearth, damper and any gas stub looked at from inside the room, so you know which conversion the opening fits.

Read more

Chimney Level 2 Inspection

A recorded camera pass from firebox to cap with attic and roof checks, booked before a fuel switch or a purchase.

Read more

Chimney Cap Installation

A top matched to both the flue size and the fuel underneath, since wood fires and gas appliances want different caps.

Read more

Chimney Flashing Repair

Leaks at the roofline beside the chimney traced and resealed with new step and counter pieces.

Read more

Chimney Masonry Repair

Spalled brick and washed-out mortar repaired so the stack holds up whether it vents logs or a gas liner.

Read more

Chimney Rebuilds

Stacks that lean, shed brick or split through rebuilt from a solid course up, ready for whichever fuel comes next.

Read more

Fireplace Cleaning

Ash, soot and glaze cleared from the firebox and doors, often the last wood job before a gas set goes in.

Read more

Gas Fireplace Cleaning

Burner ports, pilot hood and glass cleaned on log sets and inserts so the flame burns clean and the view stays clear.

Read more

Gas Fireplace Repair

Pilots that drop out, valves that stick and burners that refuse to light traced to the failed part and replaced.

Read more

Fireplace Remodel

Surround, hearth and mantel rebuilt around a new gas insert or sealed unit, planned as one job from the opening out.

Read more

Fireplace Inserts

A sealed gas insert set into the existing firebox with its own liners, turning a drafty opening into a working heater.

Read more

Pellet Stove Repair

Pellet stoves that jam, smoke or shut down mid-burn worked through on the fuel side, the air side and the controls.

Read more

Wood Stove Repair

Door rope, baffles, firebrick and stovepipe on wood stoves repaired, with a frank word on whether a gas stove makes more sense.

Read more

Gas Logs

A burner with a ceramic log set, fitted inside your existing masonry fireplace, so splitting wood can stop.

Read more

Chimney Seismic Retrofit

Older brick stacks tied back or lightened so a strong shake is less likely to drop the top onto the roof.

Read more

Chimney Crown Repair

The mortar top around the flue tile patched, coated or recast so rain stops getting in at the head of the stack.

Read more

Dryer Vent Cleaning

Lint packed into the dryer duct removed from the wall cap inward, with airflow measured when we finish.

Read more

Chimney Liner Installation

Stainless liners matched to a gas insert, log set or furnace and carried the full height of the old flue.

Read more

Chimney Leak Repair

Water coming in at the chimney followed to where it enters, then stopped there rather than at the stain.

Read more

Chimney Waterproofing

Brick and mortar treated with a vapor-open sealer that sheds rain while trapped damp can still dry out.

Read more

Chimney Damper Repair

Throat dampers that stick, rust or leak air repaired, replaced or swapped for a gasketed top-mounted seal.

Read more

Chimney Chase Cover

Rusted lids on framed chimneys replaced with a stainless cover made to measure that throws water off the chase.

Read more
Call (657) 233-4521