The Right Size Pipe for the Fire You Are Switching To

Ask About Chimney Liner Installation

What This Job Involves

Gas appliances make plenty of water vapor and run cooler exhaust than wood, and an old clay flue that is too big or cracked lets that vapor condense and eat the mortar. A stainless liner matched to the appliance fixes both the draft and the damp. Inserts usually take a pair of liners, one out and one in. We install it, finish the top so rain cannot slip between liner and tile, and show you footage of the finished run.

Liner diameter taken from the appliance manual
Paired liners for sealed gas inserts
Old damper removed where the liner needs room
Top finished so rain stays out of the gap
Footage of the finished run

Why the Liner Changes With the Fuel

The old clay tile in a Fullerton chimney was sized for an open wood fire, which sends a large volume of smoke up a wide flue. A gas appliance makes far less exhaust, and a lot of it is water vapor. Send that small, damp flow up a big cold masonry flue and it slows, cools and condenses before it reaches the top. The water runs down the tile, soaks the mortar, and in time can stain the brick outside or rust the damper. A liner fixes that by giving the exhaust a pipe the right size for the appliance. Gas inserts usually call for a stainless liner of a specific diameter, and many use two pipes, one bringing in outside air and one taking exhaust out. Vented log sets often use the old flue as it is, but only if the tile is sound. Wood stoves and wood inserts need a heavier stainless liner rated for the higher heat.

The other reason for a liner is damage. A flue with cracked tiles, missing mortar between them or a gap where the tile has shifted is not safe for any fuel. Relining gives the exhaust a continuous path again without taking the chimney apart. We judge that with a camera, ideally during a Level 2 inspection, and the report shows exactly where the damage is. That is also where the fuel question comes back in. A liner sized for a gas insert is smaller and lighter than one sized for a wood stove, and it costs less. If you are relining a damaged flue anyway, settling the fuel first means you buy one liner rather than two. When the decision is still open, we price both sizes on the same quote so the difference is clear before you commit.

The Installation and the Quote

On install day the damper is usually removed, since its frame narrows the throat. The liner is lowered from the roof, connected at the bottom to the appliance outlet, and secured at the top with a plate fastened to the crown and a rain cap above it. On chimneys where the gap around the liner is tight to wood framing, insulation is wrapped around the pipe before it goes in. We then run the appliance and check the draft, and a short camera pass confirms the liner sits cleanly in the flue. For an insert, the liner connects to the insert's outlet before the unit is pushed into place, with a flexible section at the bottom to make the bend through the throat. For a wood stove, the liner meets the stove pipe with a tee or a straight connector, depending on how the stove sits.

The quote depends on the chimney height, the liner diameter and type, whether insulation is needed, and whether the old damper or smoke shelf has to be cut back to make room. Those vary so much that the written figure follows the measurements and the scan. When the liner is part of an insert installation, it is included in the insert price band of $2,850 to $5,700 rather than charged on its own. Describe the appliance you have or plan to install on the contact page. A tall two story chimney with an offset flue is the hardest case, since the liner has to be worked around the bend from above. A short single story chimney with a straight flue is the simplest. Most homes in Fullerton are closer to the second, which keeps the cost down.

How Murdoch Chimney Group Works

Flue Before Fuel

The chimney is checked before any gas unit is chosen

Options Compared

Logs, insert and sealed unit laid out next to each other

Figures on Paper

Scope and cost written down before tools come out

Photos With Reports

What we saw, shown as well as described

Where we offer chimney liner installation

Search for your city. Fullerton, La Habra, Buena Park and Yorba Linda have their own pages with local housing notes.

All cities

Nothing found under that name. Check the spelling, or open the full city list.

More from our service list

Chimney Sweep

Tar and soot cleared out of a wood flue, often the first job before gas logs or an insert move into the same opening.

Read more

Chimney Inspection

Flue, crown, damper and firebox reviewed so you learn what a gas switch would ask of the chimney you already own.

Read more

Chimney Repair

Broken tile, open joints and leaks put right in the order a gas appliance needs them, before anything is lit.

Read more

Fireplace Inspection

Firebox, hearth, damper and any gas stub looked at from inside the room, so you know which conversion the opening fits.

Read more

Fireplace Repair

Cracked firebrick, worn refractory panels, sunken hearths and tired doors repaired so the opening suits wood or gas.

Read more

Chimney Level 2 Inspection

A recorded camera pass from firebox to cap with attic and roof checks, booked before a fuel switch or a purchase.

Read more

Chimney Cap Installation

A top matched to both the flue size and the fuel underneath, since wood fires and gas appliances want different caps.

Read more

Chimney Flashing Repair

Leaks at the roofline beside the chimney traced and resealed with new step and counter pieces.

Read more

Chimney Masonry Repair

Spalled brick and washed-out mortar repaired so the stack holds up whether it vents logs or a gas liner.

Read more

Chimney Rebuilds

Stacks that lean, shed brick or split through rebuilt from a solid course up, ready for whichever fuel comes next.

Read more

Fireplace Cleaning

Ash, soot and glaze cleared from the firebox and doors, often the last wood job before a gas set goes in.

Read more

Gas Fireplace Cleaning

Burner ports, pilot hood and glass cleaned on log sets and inserts so the flame burns clean and the view stays clear.

Read more

Gas Fireplace Repair

Pilots that drop out, valves that stick and burners that refuse to light traced to the failed part and replaced.

Read more

Fireplace Remodel

Surround, hearth and mantel rebuilt around a new gas insert or sealed unit, planned as one job from the opening out.

Read more

Fireplace Inserts

A sealed gas insert set into the existing firebox with its own liners, turning a drafty opening into a working heater.

Read more

Pellet Stove Repair

Pellet stoves that jam, smoke or shut down mid-burn worked through on the fuel side, the air side and the controls.

Read more

Wood Stove Repair

Door rope, baffles, firebrick and stovepipe on wood stoves repaired, with a frank word on whether a gas stove makes more sense.

Read more

Gas Logs

A burner with a ceramic log set, fitted inside your existing masonry fireplace, so splitting wood can stop.

Read more

Chimney Seismic Retrofit

Older brick stacks tied back or lightened so a strong shake is less likely to drop the top onto the roof.

Read more

Chimney Crown Repair

The mortar top around the flue tile patched, coated or recast so rain stops getting in at the head of the stack.

Read more

Dryer Vent Cleaning

Lint packed into the dryer duct removed from the wall cap inward, with airflow measured when we finish.

Read more

Chimney Leak Repair

Water coming in at the chimney followed to where it enters, then stopped there rather than at the stain.

Read more

Chimney Waterproofing

Brick and mortar treated with a vapor-open sealer that sheds rain while trapped damp can still dry out.

Read more

Chimney Damper Repair

Throat dampers that stick, rust or leak air repaired, replaced or swapped for a gasketed top-mounted seal.

Read more

Chimney Chase Cover

Rusted lids on framed chimneys replaced with a stainless cover made to measure that throws water off the chase.

Read more

Wood-to-gas guides from Murdoch Chimney Group

Call (657) 233-4521